Rigol MSO1000Z Series Programming Manual page 51

Digital oscilloscope
Hide thumbs Also See for MSO1000Z Series:
Table of Contents

Advertisement

Chapter 2 Command System
:CURSor:XY:BY
Syntax
:CURSor:XY:BY <y>
:CURSor:XY:BY?
Description
Set or query the vertical position of cursor B in the XY cursor measurement mode.
Parameter
Name
<x>
Explanation
In the XY timebase mode, the horizontal and vertical positions are defined by the pixel
coordinate of the XY display area. The pixel coordinate of the XY display area ranges from
(0,0) to (400,400). Wherein, (0,0) is located at the right top corner and (400,400) is
located at the left bottom corner. The horizontal and vertical pixel ranges are both from 0
to 400.
Return
The query returns an integer between 5 and 394.
Format
Example
:CURSor:XY:BY 200
:CURSor:XY:BY?
:CURSor:XY:AXValue?
Syntax
:CURSor:XY:AXValue?
Description
Query the X value of cursor A in the XY cursor measurement mode. The unit depends on
the amplitude unit of the corresponding channel.
Return
The query returns the X value of cursor A in scientific notation.
Format
Example
:CURSor:XY:AXValue?
Related
:CHANnel<n>:UNITs
Command
:CURSor:XY:AYValue?
Syntax
:CURSor:XY:AYValue?
Description
Query the Y value of cursor A in the XY cursor measurement mode. The unit depends on
the amplitude unit of the corresponding channel.
Return
The query returns the Y value of cursor A in scientific notation.
Format
Example
:CURSor:XY:AYValue?
Related
:CHANnel<n>:UNITs
Command
MSO1000Z/DS1000Z Programming Guide
Type
Range
Integer
5 to 394
/*Set the vertical position of cursor B to 200*/
/*The query returns 200*/
/*The query returns 2.000000e+00*/
/*The query returns 2.000000e+00*/
RIGOL
Default
300
2-35