Rigol MSO1000Z Series Programming Manual page 62

Digital oscilloscope
Hide thumbs Also See for MSO1000Z Series:
Table of Contents

Advertisement

RIGOL
:DECoder<n>:UART:ENDian
Syntax
:DECoder<n>:UART:ENDian <endian>
:DECoder<n>:UART:ENDian?
Description
Set or query the endian of RS232 decoding.
Parameter
Name
<n>
<endian>
Return
The query returns LSB or MSB.
Format
Example
:DECoder1:UART:ENDian MSB
:DECoder1:UART:ENDian?
:DECoder<n>:UART:BAUD
Syntax
:DECoder<n>:UART:BAUD <baud>
:DECoder<n>:UART:BAUD?
Description
Set or query the buad rate of RS232 decoding. The default unit is bps (baud per second).
Parameter
Name
<n>
<baud>
Return
The query returns the current baud rate in integer.
Format
Example
:DECoder1:UART:BAUD 57600
:DECoder1:UART:BAUD?
:DECoder<n>:UART:WIDTh
Syntax
:DECoder<n>:UART:WIDTh <wid>
:DECoder<n>:UART:WIDTh?
Description
Set or query the width of each frame of data in RS232 decoding.
Parameter
Name
<n>
<wid>
Return
The query returns an integer between 5 and 8.
Format
Example
:DECoder1:UART:WIDTh 7
:DECoder1:UART:WIDTh?
2-46
Type
Range
Discrete
{1|2}
Discrete
{LSB|MSB}
/*Set the endian of RS232 decoding to MSB*/
/*The query returns MSB*/
Type
Range
Discrete
{1|2}
Integer
110 to 20M
/*Set the buad rate of RS232 decoding to 57600bps*/
/*The query returns 57600*/
Type
Range
Discrete
{1|2}
Integer
5 to 8
/*Set the data width in RS232 decoding to 7*/
/*The query returns 7*/
Chapter 2 Command System
MSO1000Z/DS1000Z Programming Guide
Default
--
LSB
Default
--
9600
Default
--
8