:TRIGger:NEDGe:IDLE
Syntax
:TRIGger:NEDGe:IDLE <NR3>
:TRIGger:NEDGe:IDLE?
Description
Set or query the idle time in Nth edge trigger. The default unit is s.
Parameter
Return Format
The query returns the idle time in scientific notation.
Example
:TRIGger:NEDGe:IDLE 0.002
:TRIGger:NEDGe:IDLE?
:TRIGger:NEDGe:EDGE
Syntax
:TRIGger:NEDGe:EDGE <NR1>
:TRIGger:NEDGe:EDGE?
Description
Set or query the number of edges in Nth edge trigger.
Parameter
Return Format
The query returns an integer between 1 and 65535.
Example
:TRIGger:NEDGe:EDGE 20
:TRIGger:NEDGe:EDGE?
:TRIGger:NEDGe:LEVel
Syntax
:TRIGger:NEDGe:LEVel <level>
:TRIGger:NEDGe:LEVel?
Description
Set or query the trigger level in Nth edge trigger. The unit is the same as the current
amplitude unit.
Parameter
Explanation
Return Format
The query returns the trigger level in scientific notation.
Example
:TRIGger:NEDGe:LEVel 0.16
:TRIGger:NEDGe:LEVel?
2-200
Name
Type
Range
<NR3>
Real
16ns to 10s
Name
Type
Range
<NR1>
Integer
1 to 65535
Name
Type
Range
(-5 x VerticalScale - OFFSet) to
<level>
Real
(5 x VerticalScale - OFFSet)
For VerticalScale, refer to :CHANnel<n>:SCALe. For OFFSet, refer
to :CHANnel<n>:OFFSet.
This command is only available when the signal source is an analog channel.
/*Set the idle time to 2ms*/
/*The query returns 2.000000e-03*/
/*Set the number of edges to 20*/
/*The query returns 20*/
/*Set the trigger level to 160mV*/
/*The query returns 1.600000e-01*/
MSO1000Z/DS1000Z Programming Guide
Chapter 2 Command System
Default
1μs
Default
2
Default
0