Chapter 2 Command System
:DECoder<n>:IIC:ADDRess
Syntax
:DECoder<n>:IIC:ADDRess <addr>
:DECoder<n>:IIC:ADDRess?
Description
Set or query the address mode of I2C decoding.
Parameter
Name
<n>
<addr>
Explanation
NORMal: the address bits (:TRIGger:IIC:AWIDth) does not include the R/W bit.
RW: the address bits (:TRIGger:IIC:AWIDth) includes the R/W bit.
Return
The query returns NORM or RW.
Format
Example
:DECoder1:IIC:ADDRess RW
:DECoder1:IIC:ADDRess?
MSO1000Z/DS1000Z Programming Guide
Type
Range
Discrete
{1|2}
Discrete
{NORMal|RW}
/*Set the address of I2C decoding to include the R/W
bit*/
/*The query returns RW*/
RIGOL
Default
--
NORMal