Chapter 2 Command System
:DECoder<n>:UART:STOP
Syntax
:DECoder<n>:UART:STOP <stop>
:DECoder<n>:UART:STOP?
Description
Set or query the stop bit after each frame of data in RS232 decoding.
Parameter
Name
<n>
<stop>
Return
The query returns 1, 1.5, or 2.
Format
Example
:DECoder1:UART:STOP 1.5
:DECoder1:UART:STOP?
:DECoder<n>:UART:PARity
Syntax
:DECoder<n>:UART:PARity <parity>
:DECoder<n>:UART:PARity?
Description
Set or query the even-odd check mode of the data transmission in RS232 decoding.
Parameter
Name
<n>
<parity>
Return
The query returns NONE, EVEN, or ODD.
Format
Example
:DECoder1:UART:PARity ODD
:DECoder1:UART:PARity?
MSO1000Z/DS1000Z Programming Guide
Type
Range
Discrete
{1|2}
Discrete
{1|1.5|2}
/*Set the stop bit in RS232 decoding to 1.5*/
/*The query returns 1.5*/
Type
Range
Discrete
{1|2}
Discrete
{NONE|EVEN|ODD}
/*Set the even-odd check mode in RS232 decoding to
odd*/
/*The query returns ODD*/
RIGOL
Default
--
1
Default
--
NONE