Rigol MSO1000Z Series Programming Manual page 130

Digital oscilloscope
Hide thumbs Also See for MSO1000Z Series:
Table of Contents

Advertisement

RIGOL
4.
Voltage Parameters
Vmax:
The voltage value from the highest point of the waveform to the GND.
Vmin:
The voltage value from the lowest point of the waveform to the GND.
Vpp:
The voltage value from the highest point to the lowest point of the waveform.
Vtop:
The voltage value from the flat top of the waveform to the GND.
Vbase:
The voltage value from the flat base of the waveform to the GND.
Vamp:
The voltage value from the top of the waveform to the base of the waveform.
Vupper:
The actual voltage value corresponding to the threshold maximum value.
Vmid:
The actual voltage value corresponding to the threshold middle value.
Vlower:
The actual voltage value corresponding to the threshold minimum value.
Vavg:
The arithmetic average value on the whole waveform or on the gating area. The
calculation formula is as follows:
Wherein,
being measured.
Vrms:
The root mean square value on the whole waveform or the gating area. The calculation
formula is as follows:
Wherein,
being measured.
Overshoot:
The ratio of the difference between the maximum value and top value of the waveform
to the amplitude value.
Preshoot:
The ratio of the difference between the minimum value and base value of the waveform
to the amplitude value.
Per.Vrms:
The root mean square value within a period. For the calculation formula, please refer to
"Vrms".
Variance:
The average of the sum of the squares for the difference between the amplitude value
of each waveform point and the waveform average value on the whole waveform or on
the gating area. The variance reflects the fluctuation degree of the waveform. The
calculation formula is as follows:
Wherein,
the waveform,
Vmax
Vpp
Vmin
2-114
Average =
x is the measurement result of the ith point,
i
RMS =
x is the measurement result of the ith point,
i
Variance =
is the amplitude of the ith point, Average is the average value of
Vamp i
( )
is the number of points being measured.
n
Overshoot
Vtop
Vamp
Vbase
Preshoot
x
i
n
n
2
x
i
i=1
n
n
2
(
Vamp(i) Average
-
)
i
=1
n
MSO1000Z/DS1000Z Programming Guide
Chapter 2 Command System
is the number of points
n
is the number of points
n
Vupper
Vmid
Vlower