IO-Link Master EtherCat
Abort Code
Description
(hex)
0800 0023
Object dictionary dynamic generation fails or no object dictionary is present

32 Set-up

32.1 Factory setting
The device has the following remanent objects
– 2007
: Installation location
hex
– 200A
: Equipment identification
hex
On delivery, these objects are empty
32.2 Restore factory settings
In order to reset the objects to the factory setting, write the value "1" on the CoE
object 2F00
 After the next power-on, the factory settings of the device are
hex
restored
Index (hex)
Subindex
2F00
-
32.3 Firmware started
Once you have connected the power, the firmware is started After completion of
the firmware boot process, the LED RDY is lit green or flashes depending on the
bus status The RUN LED informs you about the current status of the internal state
machine
32.4 Firmware update
You have the option to carry out a firmware update
For this, the File Access mechanism is applied via EtherCat (FoE) that is provided
via your engineering system For detailed instructions about the firmware update
with CODESYS, please refer to chapter 36 firmware update with CODESYS V35

33 Connection monitoring/substitute value behaviour

The device executes connection monitoring of the network communication In the
event of a connection timeout, the device switches its outputs to the previously
configured safe state
For further information, please refer to chapter "Safe State Objects"
66
Object name
Type
Reset to factory
UINT8
settings
Rights
Description/value
R/W
0 = normal operation (default)
1 = reset device
Other = reserved