4.
Increase the value in 043: [Paper Transfer Current: FC: Side 1] or 044: [Paper Transfer
Current: FC: Side 2] by -20 A.
Eg., -120 A to -100 A
5.
Print the image. Has the problem been resolved?
Yes
Finished!
No
Decrease the value in 087: [Ppr Trns High Pressure Setting] by one step. If [High] is
selected, change the value to [Standard]. If [Standard] is selected, change the value to
[Low]. If [Low] is selected, change the value to [Off].
6.
Print the image. Has the problem been resolved?
Yes
Finished!
No
Contact your service representative.
• After performing the solution, it is recommended to perform the color calibration of the external
controller. For details see, page 159 "Operating Procedure for Color Calibration".
Mottling
Mottling occurs in solid-filled areas.
Normal
Mottled