Download Print this page

Sets The Source Output Power Mode - Agilent Technologies EMC Series Programmer's Manual

Spectrum analyzers 9 khz-1.5/3.0/6.7/13.2/26.5 ghz
Hide thumbs Also See for EMC Series:

Advertisement

Power-level sensitive devices connected to the tracking generator output may be
CAUTION
accidentally damaged. This is because the actual source amplitude may be greater
than the amplitude indicated on the analyzer when the source attenuation is set
manually.
When source attenuation is set to manual
(:SOURce:POWer:ATTenuation:AUTO OFF), source amplitude may be set to
values beyond actual output levels to accommodate the full range of analyzer
capabilities. Therefore, exercise caution when connecting a power-level sensitive
device to the tracking generator output.
Factory Preset
and *RST:
Range:
Default Unit:
Front Panel
Access:

Sets the Source Output Power Mode

:SOURce:POWer:MODE FIXed|SWEep
:SOURce:POWer:MODE?
Sets the source output to be at a single amplitude (fixed) or to sweep through a
range of power levels.
Factory Preset
and *RST:
Front Panel
Access:
Set the Source Sweep Power Range
:SOURce:POWer:SPAN <rel_ampl>
:SOURce:POWer:SPAN?
Specifies the range of power levels through which the source output will sweep.
Use :SOURce:POWer:STARt to set the power level at the start of the power
sweep. This command is equivalent to :SOURce:POWer:SWEep.
Chapter 5
97 dBµV
EMC E7401A: 37 dBµV to 110 dBµV
EMC E7402A: 41 dBµV to 110 dBµV
EMC E7403A: 41 dBµV to 110 dBµV
EMC E7404A: 41 dBµV to 110 dBµV
EMC E7405A: 41 dBµV to 110 dBµV
dBm
Source, Amplitude On Off
Fixed
Source, Power Sweep On Off
Language Reference