Download Print this page

Type Of Averaging For Measurements - Agilent Technologies EMC Series Programmer's Manual

Spectrum analyzers 9 khz-1.5/3.0/6.7/13.2/26.5 ghz
Hide thumbs Also See for EMC Series:

Advertisement

Factory Preset
and *RST:
History:
Front Panel
Access:

Type of Averaging for Measurements

[:SENSe]:AVERage:TYPE VIDeo|RMS
[:SENSe]:AVERage:TYPE?
Successive measurements of data can be combined to average out measurement
variations. Detector is set to average and Avg type is set to power (RMS) to
measure RMS voltage (avg power).
As a best practice, set amplitude scale (:DISP:WIND:TRAC:Y:SPAC) prior to
NOTE
average type.
The following parameters of this command are supported, but not recommended
for new designs. They are provided for limited compatibility to other analyzers.
When used, the parameters are converted as follows:
Factory Preset
and *RST:
History:
Front Panel
Access:
Chapter 5
On
Added with firmware revision A.08.00.
BW/Avg, Avg Type, Auto Man
VIDeo logarithmically averages the power of the video data (typical units are
dBm). This command is equivalent to pressing front panel keys
Type, Video.
RMS averages the linear power of successive measurements (typical units are
watts).
TYPE LINear maps to RMS.
TYPE LPOWer maps to VIDeo.
TYPE POWer maps to RMS.
TYPE SCALar and VOLTage will map to VIDeo. If the amplitude scale is LOG, the
setting is allowed, but an error is generated.
TYPE LOG maps to VIDeo. If the amplitude scale is not LOG (linear or Y Axis Units
= Hz), the setting is allowed, but an error is generated.
For compatibility with firmware revisions prior to A.08.00, q
[:SENSe]:AVERage:TYPE? will return LPOW or POW if LPOW or POW is used
during the setting and no further changes have occurred to set the average type (such as
from the front panel).
VID
Changed with firmware revision A.08.00.
BW/Avg, Avg Type
Language Reference
[:SENSe]:AVERage Subsection
BW/Avg, Avg
uery