Description of parameters
2.8.1
MF Mode
This parameter is used when you have two drives in Shaft Generator operation and the
drives must operate to an upper system as a single unit.
0 = Single drive
System bus is deactivated. For example, in Shaft Generator system both drives are
controlled separately.
1 = Master
The drive sends a control word to the follower drive. For example, in Shaft Generator
system both drives must operate as a single drive.
2 = Follower
The drive receives a control word from the master drive and sends diagnostic
information back.
3 = Master: Mode 2
NOTE! Requires a uGrid Licence (P3.2 uGrid Licence)
See chapter Licences.
4 = Follower: Mode 2
NOTE! Requires a uGrid Licence (P3.2 uGrid Licence).
See chapter Licences.
2.8.2
SB Comm. Fault
This parameter defines the response when the system bus heartbeat is missing.
The master drive sends a heartbeat signal to all follower drives and this heartbeat is
sent back to the master drive.
2.8.3
SB Fault Delay
This parameter defines the delay before a fault generation when the heartbeat is
missing.
2.8.4
MF Mode 3 Licence
Enter a licence for MF Mode 5 and 6 operation if requested by factory.
See chapter Licences.