Danfoss VLT AutomationDrive FC 302 Design Manual page 43

90–710 kw, enclosure sizes d and e
Hide thumbs Also See for VLT AutomationDrive FC 302:
Table of Contents

Advertisement

Specifications
®
VLT
AutomationDrive FC 302
High/normal overload
(High overload=150% current during 60 s,
normal overload=110% current during 60 s)
Typical Shaft output at 525 V [kW]
Typical Shaft output at 575 V [hp]
Typical Shaft output at 690 V [kW]
Enclosure size
Output current (3-phase)
Continuous (at 525 V) [A]
Intermittent (60 s overload) (at 525 V)[A]
Continuous (at 575/690 V) [A]
Intermittent (60 s overload) (at 575/690 V) [A]
Continuous kVA (at 525 V) [kVA]
Continuous kVA (at 575 V) [kVA]
Continuous kVA (at 575/690 V) [kVA]
Maximum input current
Continuous (at 525 V) [A]
Continuous (at 575/690 V)
Maximum number and size of cables per phase
- Mains, motor, brake, and load share
2
[mm
(AWG)]
Maximum external mains fuses [A]
Estimated power loss at 575 V [W]
Estimated power loss at 690 V [W]
3)
Efficiency
Output frequency [Hz]
Heat sink overtemperature trip [°C (°F)]
Control card overtemperature trip [°C (°F)]
Table 7.6 Electrical Data for Enclosures D2h/D4h/D7h/D8h, Mains Supply 3x525–690 V AC
1) For fuse ratings, see chapter 10.5 Fuses and Circuit Breakers.
2) Typical power loss is at normal conditions and expected to be within
values are based on a typical motor efficiency (IE/IE3 border line). Lower efficiency motors add to the power loss in the drive. Applies for
dimensioning of drive cooling. If the switching frequency is higher than the default setting, the power losses can increase. LCP and typical control
card power consumptions are included. For power loss data according to EN 50598-2, refer to drives.danfoss.com/knowledge-center/energy-
efficiency-directive/#/. Options and customer load can add up to 30 W to the losses, though usually a fully loaded control card and options for
slots A and B each add only 4 W.
3) Measured using 5 m (16.4 ft) shielded motor cables at rated load and rated frequency. Efficiency measured at nominal current. For energy
efficiency class, see chapter 10.11 Efficiency. For part load losses, see drives.danfoss.com/knowledge-center/energy-efficiency-directive/#/.
MG38C202
Design Guide
N160
HO
NO
132
160
200
250
160
200
201
253
301
278
192
242
288
266
183
230
191
241
229
289
193
244
185
233
2x185 (2x350)
550
1)
2361
3074
2), 3)
2), 3)
2446
3175
0.98
0–590
110 (230)
80 (176)
Danfoss A/S © 01/2018 All rights reserved.
N200
HO
NO
HO
160
200
200
250
300
300
200
250
250
D2h/D4h/D7h/D8h
253
303
303
380
333
455
242
290
290
363
319
435
230
276
276
241
289
289
289
347
347
244
292
292
233
279
279
2x185 (2x350)
2x185 (2x350)
550
3012
3723
3642
3123
3851
3771
0.98
0–590
110 (230)
110 (230)
80 (176)
± 15% (tolerance relates to variety in voltage and cable conditions). These
N250
N315
NO
HO
NO
250
250
315
350
350
400
315
315
400
360
360
418
396
540
460
344
344
400
378
516
440
327
327
380
343
343
398
411
411
478
347
347
403
332
332
385
2x185 (2x350)
550
550
4465
4146
5028
4614
4258
5155
0.98
0.98
0–590
0–590
110 (230)
80 (176)
80 (176)
7
7
41