Danfoss VLT AutomationDrive FC 302 Design Manual page 201

90–710 kw, enclosure sizes d and e
Hide thumbs Also See for VLT AutomationDrive FC 302:
Table of Contents

Advertisement

How to Order a Drive
LCP kit, IP21
LCP kit, IP21
LCP kit, IP21
External options
EtherNet/IP
Table 13.11 Kits Available for Enclosures D1h–D8h
13.2.7 Ordering Numbers for E1h–E4h Kits
Type
Miscellaneous hardware
PROFIBUS top entry, E1h–E4h
USB in the door, E1h–E4h
Ground bar
Mains shield, E1h
Mains shield, E2h
Terminal blocks
Back-channel cooling kits
In bottom/out top, E3h
In bottom/out top, E3h
In bottom/out top, E4h
In back/out back, E1h
In back/out back, E2h
In back/out back, E3h
In back/out back, E4h
In bottom/out back, E3h
In bottom/out back, E3h
In bottom/out back, E4h
In back/out top, E3h
In back/out top, E4h
MG38C202
Design Guide
Panel mounting kit including graphical LCP, fasteners, 3 m (9 ft) cable
and gasket.
Panel mounting kit including numerical LCP, fasteners and gasket.
Panel mounting kit for all LCPs including fasteners, 3 m (9 ft) cable
and gasket.
Ethernet master.
Description
Top entry for enclosure protection rating IP54.
USB extension cord kit to allow access to the drive controls via laptop
computer without opening the drive.
More grounding points for E1h and E2h drives.
Shielding (cover) mounted in front of the power terminals to protect
from accidental contact.
Shielding (cover) mounted in front of the power terminals to protect
from accidental contact.
Screw terminal blocks for replacing spring loaded terminals.
(1 pc 10 pin 1 pc 6 pin and 1 pc 3-pin connectors)
Allows the cooling air to be directed in through the bottom and out
through the top of the drive. This kit is used only for enclosure E3h
with the 600 mm (21.6 in) base plate.
Allows the cooling air to be directed in through the bottom and out
through the top of the drive. This kit used only for enclosure E3h with
800 mm (31.5 in) base plate.
Allows the cooling air to be directed in through the bottom and out
through the top of the drive. This kit is used only for enclosure E4h
with the 800 mm (31.5 in) base plate.
Allows the cooling air to be directed in and out through the back of
the drive. This kit is used only for enclosure E1h.
Allows the cooling air to be directed in and out through the back of
the drive. This kit is used only for enclosure E2h.
Allows the cooling air to be directed in and out through the back of
the drive. This kit is used only for enclosure E3h.
Allows the cooling air to be directed in and out through the back of
the drive. This kit is used only for enclosure E4h.
Allows the cooling air to be directed in through the bottom and out
through the back of the drive. This kit is used only for enclosure E3h
with the 600 mm (21.6 in) base plate.
Allows the cooling air to be directed in through the bottom and out
through the back of the drive. This kit used only for enclosure E3h
with the 800 mm (31.5 in) base plate.
Allows the cooling air to be directed in through the bottom and out
through the back of the drive. This kit is used only for enclosure E4h
with 800 mm (31.5 in) base plate.
Allows the cooling air to be directed in through the back and out
through the top of the drive. This kit is used only for enclosure E3h.
Allows the cooling air to be directed in through the back and out
through the top of the drive. This kit is used only for enclosure E4h.
Danfoss A/S © 01/2018 All rights reserved.
130B1113
130B1114
130B1117
175N2584
Ordering number
176F1742
130B1156
176F6609
176F6619
176F6620
130B1116
Standard
Stainless steel
176F6606
176F6607
176F6608
176F6617
176F6618
176F6610
176F6611
176F6612
176F6613
176F6614
176F6615
176F6616
199
13
13