90–710 kw, enclosure sizes d and e
Hide thumbs Also See for VLT AutomationDrive FC 302:
Table of Contents

Advertisement

How to Order a Drive
Back-channel duct kit, D4h
Pedestal, D1h
Pedestal, D2h
Pedestal, D5h/D6h
Pedestal, D7h/D8h
Top entry of fieldbus cables,
D1h–D8h
USB in the door, D1h–D8h
(IP20/chassis)
USB in the door, D1h–D8h
(IP21/Type 1 and IP54/Type 12)
Input plate option, D1h–D8h
Terminal blocks
Back-channel cooling kits
In-back/out-back (Non-Rittal
enclosures), D3h
In-back/out-back (Non-Rittal
enclosures), D4h
In bottom/out back, D1h/D3h
13
13
In bottom/out back, D2h/D4h
In back/out back, D1h
In back/out back, D2h
In back/out back, D3h
In back/out back, D4h
In back/out back, D5h/D6h
In back/out back, D7h/D8h
LCP
LCP 101
LCP 102
LCP cable
198
VLT® AutomationDrive FC 302
Duct kit that converts enclosure to either in-bottom/out-top venting
or top only venting. Enclosure size: 2000 mm (78.7 in).
Provides a 400 mm (15.7 in) pedestal that allows the drive to be floor
mounted. The front of the pedestal has openings for input air to cool
the power components.
Provides a 400 mm (15.7 in) pedestal that allows the drive to be floor
mounted. The front of the pedestal has openings for input air to cool
the power components.
Provides a 200 mm (7.9 in) pedestal that allows the drive to be floor
mounted. The front of the pedestal has openings for input air to cool
the power components.
Provides a 200 mm (7.9 in) pedestal that allows the drive to be floor
mounted. The front of the pedestal has openings for input air to cool
the power components.
Allows for the installation of fieldbus cables through the top of the
drive. The kit is IP20/chassis when installed, but a different mating
connector can be used to increase the protection rating.
USB extension cord kit to allow access to the drive controls via laptop
computer without opening the drive.
USB extension cord kit to allow access to the drive controls via laptop
computer without opening the drive.
Allows fuses, disconnect/fuses, RFI, FRI/fuses, and RFI/disconnect/fuses
options to be added.
Screw terminal blocks for replacing spring loaded terminals.
(1 pc 10 pin 1 pc 6 pin and 1 pc 3-pin connectors)
Allows the cooling air to be directed in and out through the back of
the drive. Does not include plates for mounting in the enclosure. This
kit is used only for enclosure D3h.
Allows the cooling air to be directed in and out through the back of
the drive. Does not include plates for mounting in the enclosure. This
kit is used only for enclosure D4h.
Allows the cooling air to be directed in through the bottom and out
through the back of the drive. This kit is used only for enclosures
D1h/D3h.
Allows the cooling air to be directed in through the bottom and out
through the back of the drive. This kit is used only for enclosures
D2h/D4h.
Allows the cooling air to be directed in and out through the back of
the drive. This kit is used only for enclosure D1h.
Allows the cooling air to be directed in and out through the back of
the drive. This kit is used only for enclosure D2h.
Allows the cooling air to be directed in and out through the back of
the drive. This kit is used only for enclosure D3h.
Allows the cooling air to be directed in and out through the back of
the drive. This kit is used only for enclosure D4h.
Allows the cooling air to be directed in and out through the back of
the drive. This kit is used only for enclosures D5h/D6h.
Allows the cooling air to be directed in and out through the back of
the drive. This kit is used only for enclosures D7h/D8h.
Numerical local control panel (NLCP).
Graphical Local control panel (GLCP).
Separate LCP cable, 3 m (9 ft).
Danfoss A/S © 01/2018 All rights reserved.
176F3630
176F3631
176F3632
176F3452
176F3539
176F3594
Contact factory
Contact factory
Contact factory
130B1116
Standard
Stainless steel
176F3519
176F3520
176F3524
176F3525
176F3522
176F3523
176F3527
176F3528
176F3648
176F3656
176F3649
176F3657
176F3625
176F3654
176F3626
176F3655
176F3530
176F3531
130B1124
130B1107
175Z0929
MG38C202