CORRECTING
CO LEVEL ON AIR FLOW SENSOR
Note
If CO level is not the specified value. remove plug
from hole providing
access to the mixture control
screw. This requires removal of the air flow sensor.
Removing
1. Remove air flow sensor
2. Drill hole in plug with a 2 mm dia. drill bit (UP: to
stop on steel insert).
3. Pull out plug with a left-turning
drill (no. 2).
3. Close hole providing
access to mixture
control
screw with a new plug after finishing adjust-
ments. Press in plug flush.
Installing
1. Install air flow sensor.
2. Adjust engine idle speed and CO level. Turn
mixture control screw accordingly
with a rcrew-
driver.
Turning clockwise
= richer mixture
Turning anticlockwise
= leaner mixture
Note
Never reuse a drilled plug I
24.24