Siemens SINUMERIK Series Function Manual page 851

Extended functions
Hide thumbs Also See for SINUMERIK Series:
Table of Contents

Advertisement

Online request interface
DB19 DBW100
Client_Ident
DB19 DBW102
Client_Ident
DB19 DBW104
Client_Ident
DB19 DBB106
HMI type from NETNAMES.INI
DB19 DBB107
MCP address from NETNAMES.INI
255
DB19 DB108
ONL_PERM (5)
DB19 DBB109
No. of HMI-PLC online interface, OK
(10)
MMC_LOCKED (13)
PLC_LOCKED (14)
PRIO_H (15)
Extended Functions
Function Manual, 03/2013, 6FC5397-1BP40-3BA1
ONL_REQUEST
Control unit would like to go online and use the online request interface. HMI first
writes its Client_Ident as a request.
Bit 8 .. 15: Bus type: MPI 1 or BTSS 2
Bit 0 .. 7: HMI bus address
ONL_CONFIRM.
If the online request interface is not being used by another control unit, the PLC
returns the Client identification as positive acknowledgement.
Bit 8 .. 15: Bus type: MPI 1 or BTSS 2
Bit 0 .. 7: HMI bus address
PAR_CLIENT_IDENT HMI parameter transfer to PLC
Bit 8 .. 15: Bus type: MPI 1 or BTSS 2
Bit 0 .. 7: HMI bus address
PAR_MMC_TYP HMI parameter transfer to PLC
Type properties of the control unit configured in file NETNAMES.INI. Evaluated
by the PLC when MMC is suppressed (server, main/secondary operator panel,
...), see description of file NETNAMES.INI
PAR_MSTT_ADR HMI parameter transfer to PLC
Address of MCP to be switched over or activated/deactivated with the control
unit.
Parameter from NETNAMES.INI
No MCP is assigned to control unit, no MCP will be activated/deactivated
PAR_STATUS PLC sends HMI pos./neg. online permission
PLC notifies HMI as to whether control unit can go online or not. The meaning of
the signal is dependent on PAR_Z_INFO:
PAR_Z_INFO PLC sends HMI pos./neg. online permission
PLC issues the online enabling command to the requesting control unit.
Control unit can then go online to this NCU.
Bit 0 ..3: Set
Bit 4 .. 7: No. of HMI-PLC online interface with which the control unit should
connect:
First HMI-PLC online interface
Second HMI-PLC online interface
The requesting control unit cannot go online. Two control units on which
uninterruptible processes are in progress are connected online to this NCU. The
PLC cannot suppress either of the two control units.
The control unit switchover disable is set in the HMI-PLC interface.
The requesting control unit cannot go online. Two control units that are both
higher priority than the requesting control unit are connected online to the NCU.
The PLC cannot suppress either of the two control units.
Z2: NC/PLC interface signals
18.2 Distributed systems (B3)
851