DB10
DBB64, 190 - 193
Setpoint for digital NCK outputs
Edge evaluation: No
Signal state 1 or
The NCK value for the digital output currently set (setpoint) is "1".
edge change 0 → 1
Signal state 0 or
The NCK value for the digital output currently set (setpoint) is "0".
edge change 1 → 0
Signal irrelevant for
This 'setpoint' is only output to the hardware output under the following conditions:
...
As soon as these conditions are fulfilled, the "setpoint" of the digital output corresponds to the
"actual value".
Corresponding to ....
DB10 DBB4 (Disable digital NCK outputs)
DB10 DBB5 (Overwrite screen form for digital NCK outputs)
DB10 DBB6 (Setting value by PLC of digital NCK outputs)
DB10 DBB7 (Setting mask for digital NCK outputs)
MD10310 $MN_FASTIO_DIG_NUM_OUTPUTS
DB10
DBB194 - 209
Actual value for analog NCK inputs
Edge evaluation: No
Signal state 1 or
The analog value applied to the analog NCK input is signalled to the PLC.
edge change 0 → 1
The actual value is set as a fixed point number (16 bit value including sign) in 2's complement by
the NCK.
Signal state 0 or
The effect of the PLC on the analog value (e.g. with IS "Disable analog NCK inputs") is ignored.
edge change 1 → 0
Corresponding to ....
DB10 DBB146 (Disable analog NCK inputs)
DB10 DBB147 (Setting screen form of analog NCK inputs)
DB10 DBB148-163 (Setting by PLC of analog NCK inputs)
MD10300 $MN_FASTIO_ANA_NUM_INPUTS
DB10
DBB210 - 225
Setpoint for analog NCK outputs
Edge evaluation: No
Signal state 1 or
The current set NCK value for the analog output (setpoint) is signalled to the PLC.
edge change 0 → 1
The set value is set as a fixed point number (16 bit value including sign) in 2's complement by the
NCK.
Extended Functions
Function Manual, 03/2013, 6FC5397-1BP40-3BA1
Signal(s) updated: Cyclic
Output is not disabled (IS "Disable digital NCK outputs")
PLC has switched to the NCK value (IS "Setting screen form for digital NCK inputs")
Signal(s) updated: Cyclic
Signal(s) updated: Cyclic
Z2: NC/PLC interface signals
18.1 Digital and analog NCK I/Os (A4)
845