Siemens SINUMERIK Series Function Manual page 717

Extended functions
Hide thumbs Also See for SINUMERIK Series:
Table of Contents

Advertisement

Example
Block change behavior after
Program code
N51 SPOS=10 SPOS[2]=10
N52 COUPDEF(S2,S1,1,1,"FINE","DV")
N53 COUPON(S2,S1,77)
N54 M0
N57 COUPOF(S2,S1)
N99 M30
Reset and recovery
Resetting the IS "Disable synchronization" (DB31, ... DBX31.5) has no effect on the following
spindle offset. If the offset motion of the following spindle has been suppressed by the VDI
interface signal, then the offset is not automatically applied when the VDI signal is reset.
Synchronization is recovered as follows:
● By repeating the part program operation
● By setting the IS "Resynchronize" (DB31, ... DBX31.4) = 1
Extended Functions
Function Manual, 03/2013, 6FC5397-1BP40-3BA1
synchronization" (DB31, ... DBX31.5) = 0.
(FS, LS, offset) can be written e.g. in an ASUB.
COUPON
COUPON
Comment
; IS "Disable synchronization"
; set (DB31, ... DBX31.5) = 1 for S2
; Positions correspond to an offset
; of 0°
; Actual offset of 0 degrees is retained
; no following spindle movement,
; VDI signals
; IS "Synchronism coarse"
; (DB31, ... DBX98.1) and
; IS "Synchronism fine"
; (DB31, ... DBX98.0)
; are set and the block change
; enabled.
COUPON
S3: Synchronous spindle
13.1 Brief description
(FS, LS, offset) with IS "Disable
717

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 840d slSinumerik 828d

Table of Contents