Siemens SINUMERIK Series Function Manual page 457

Extended functions
Hide thumbs Also See for SINUMERIK Series:
Table of Contents

Advertisement

Value
2100..2199
2500
2501
2502
2504
2505
2506
3010..3025
3050..3065
The MEASURE( ) function calculates frame $AC_MEAS_FRAME according to the specified
frame.
In the case of values
0 to 1065, the calculation is performed using the active frame.
2000 to 3065, the calculation is performed with reference to the selected frame in data
management. The frame selection in data management is not supported for measurement
types 14 and 15. A frame does not have to be active in order to select it in data
management. In this case, the calculation is performed as if the frame were active in the
chain.
The measuring point is transformed in the selected system and the selected frame is
determined using the entire frame including the selected frame. Preset actual value memory
is active only after compensation and activation of the frame.
In the case of values
With active G500 active (1010..1025, 1050..1065, 3010..3025, 3050..3065), the target frame
is calculated so that G500 must be active after the frame is selected so that the setpoint
position can be calculated.
Conversion into another coordinate system
If a position is to be converted to a position in another coordinate system, the following
variables can be used to specify the composition of the desired frame chain:
Type
System variable
INT
$AC_MEAS_CHSFR
INT
$AC_MEAS_NCBFR
INT
$AC_MEAS_CHBFR
INT
$AC_MEAS_UIFR
INT
$AC_MEAS_PFRAME
Extended Functions
Function Manual, 03/2013, 6FC5397-1BP40-3BA1
7.5 Setting zeros, workpiece measuring and tool measuring
$P_UIFR[0..99]
$P_TOOLFR
$P_WPFR
$P_TRAFR
$P_CYCFR
$P_RELFR (workpiece
coordinate system)
$P_RELFR (SZS)
$P_CHBFR[0..15]
$P_NCBFR[0..15]
Meaning
Selection of system frames
Selection of global basic frames
Selection of channel basic frames
Selection of settable frames
Programmable frame
Meaning
settable frame in data management
System frame in data management
System frame in data management
System frame in data management
System frame in data management
System frame in data management
System frame in data management
Channel-spec. Basic frames with active G500 in
data management
NCU-global basic frames with active G500 in data
management
Values
Bit mask corresponding to MD28082
$MC_MM_SYSTEM_FRAME_MASK
Bit mask (0 ... FFFF)
Bit mask (0 ... FFFF)
0 ... 99
0: is included
1: is not included
M5: Measurement