Supplementary Conditions - Siemens SINUMERIK Series Function Manual

Extended functions
Hide thumbs Also See for SINUMERIK Series:
Table of Contents

Advertisement

● When the first valid limit is reached
● Deselection or change of the current increment (e.g. change from INC100 to INC10)
● When faults occur (e.g. on cancellation of the servo enable)
Risk of collision
If "continuous" mode is selected, several axes can by started by pressing and releasing the
relevant direction key. Any interlocks must be implemented via the PLC!
Note
While an axis is moving, a change of mode from JOG to AUTOMATIC or MDI is not
permitted within the control.
Parameter assignment
The selection of jog or continuous mode is performed NC-specifically for all axes via the
machine data:
MD11300 $MN_JOG_INC_MODE_LEVELTRIGGRD (INC and REF in jog mode)
Jogging mode is the default setting.
3.3.3

Supplementary conditions

Indexing axis
Irrespective of the set increment value, an indexing axis traverses to the next indexing
position in the direction of travel after pressing the traversing key (see Section "T1: Indexing
axes (Page 771)").
Extended Functions
Function Manual, 03/2013, 6FC5397-1BP40-3BA1
CAUTION
Traversing range limit inactive
Software limit switches and working-area limitations are only activated after reference
point approach.
WARNING
H1: Manual and handwheel travel
3.3 Incremental (JOG INC)
153

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 840d slSinumerik 828d

Table of Contents