Danfoss VLT AQUA Drive FC 202 Design Manual page 170

110-1400 kw
Hide thumbs Also See for VLT AQUA Drive FC 202:
Table of Contents

Advertisement

General Specifications and ...
High/normal load*
Typical shaft output at 400 V [kW]
Typical shaft output at 460 V [hp]
Enclosure IP21/IP54 with or without
options cabinet
Output current
Continuous (at 3x380-440 V) [A]
Intermittent (at 3x380-440 V) [A]
Continuous (at 3x441-480 V) [A]
Intermittent (at 3x441-480 V) [A]
Continuous kVA (at 400 V AC) [kVA]
Continuous kVA (at 460 V AC) [kVA]
Max. input current
Continuous (3x380-440 V) [A]
Continuous (3x441-480 V) [A]
Max. pre-fuses
1)
Max. cable size
2
Motor (mm
/AWG
Mains, F1/F2 (mm
8
8
Mains, F3/F4 (mm
Loadshare (mm
2
Brake (mm
/AWG
Estimated power loss at 400 V AC at
rated max load [W]
Estimated power loss at 460 V AC at
rated max load [W]
Max. added losses A1 RFI, CB or
disconnect, and contactor, F3/F4
Max. panel options losses
Weight, enclosure IP2, kg [lbs.]
Weight, enclosure IP54, kg [lbs.]
Weight, rectifier module, kg [lbs.]
Weight, inverter module, kg [lbs.]
4)
Efficiency
Output frequency [Hz]
Heatsink overtemp. trip [°C]
Power card ambient trip [°C]
*High overload=150% current for 60 s, Normal overload=110% current for 60 s
Table 8.3 Technical Specifications, F1-F4, Mains Supply 3x380-480 V AC
1) For type of fuse, consult the Operating Instructions.
2) American Wire Gauge.
3) The typical power loss is at normal conditions and expected to be within
These values are based on a typical motor efficiency (IE2/IE3 border line). Lower efficiency motors add to the power loss in the frequency
converter and the opposite is also true. If the switching frequency is raised from nominal, the power losses rise significantly. LCP and typical
control card power consumptions are included. Further options and customer load can add up to 30 W to the losses (though typically only 4 W
extra for a fully loaded control card or options for slot A or slot B, each).
4) Measured using 5 m screened motor cables at rated load and rated frequency.
5) Wiring terminals on N132, N160, and N315 frequency converters cannot receive cables one size larger.
168
P500
HO
450
600
800
1200
730
1095
554
582
779
711
[A]
2) 5)
)
2
/AWG
2) 5)
)
2
/AWG
2) 5)
)
2
2) 5)
/AWG
)
2) 5)
)
9031
3)
8212
3)
893
102 [224]
102 [224]
Danfoss A/S © Rev. 06/2014 All rights reserved.
Design Guide
P560
P630
NO
HO
NO
HO
500
500
560
560
650
650
750
750
F1/F3
880
880
990
990
968
1320
1089
1485
780
780
890
890
858
1170
979
1335
610
610
686
686
621
621
709
709
857
857
964
964
759
759
867
867
1600
8x150 (8x300 mcm)
8x240 (8x500 mcm)
8x456 (8x900 mcm)
4x120 (4x250 mcm)
4x185 (4x350 mcm)
10162 10146 11822 10649 12512
8876
8860
10424
9414
963
951
1054
978
1017/1318 [2242/2905]
102 [224]
102 [224]
102 [224]
102 [224]
± 15% (tolerance relates to variety in voltage and cable conditions.)
P710
P800
NO
HO
NO
HO
630
630
710
710
900
900
1000
1000
1120
1120
1260
1260
1232
1680
1386
1890
1050
1050
1160
1160
1155
1575
1276
1740
776
776
873
873
837
837
924
924
1090
1090
1227
1227
1022
1022
1129
1129
2000
12x150 (12x300 mcm)
6x185 (6x350 mcm)
12490
14674 14244 17293 15466 19278
11595
11581
13213 13005 16229 14556 16624
1093
1092
1230
2067
400
1260/1561 [2778/3441]
102 [224]
136 [299]
136 [299]
102 [224]
0.98
0-590
95
75
P1M0
NO
HO
NO
800
800
1000
1200
1200
1350
F2/F4
1460
1460
1720
1606
2190
1892
1380
1380
1530
1518
2070
1683
1012
1012
1192
1100
1100
1219
1422
1422
1675
1344
1344
1490
2500
2280
2236
2541
136 [299]
102 [224]
MG20Z202