Danfoss VLT AQUA Drive FC 202 Design Manual page 10

110-1400 kw
Hide thumbs Also See for VLT AQUA Drive FC 202:
Table of Contents

Advertisement

How to Read this Design Gui...
1
1
1.1.3 Abbreviations
Alternating current
American wire gauge
Ampere/AMP
Automatic Motor Adaptation
Current limit
Degrees Celsius
Direct current
Drive Dependent
Electro Magnetic Compatibility
Electronic Thermal Relay
Frequency converter
Gram
Hertz
Horsepower
Kilohertz
Local Control Panel
Meter
Millihenry Inductance
Milliampere
Millisecond
Minute
Motion Control Tool
Nanofarad
Newton Meters
Nominal motor current
Nominal motor frequency
Nominal motor power
Nominal motor voltage
Permanent Magnet motor
Protective Extra Low Voltage
Printed Circuit Board
Rated Inverter Output Current
Revolutions Per Minute
Regenerative terminals
Second
Synchronous Motor Speed
Torque limit
Volts
The maximum output current
The rated output current supplied by the
frequency converter
Table 1.1 Abbreviations
1.1.4 Definitions
Frequency converter:
Input:
I
VLT,MAX
The maximum output current.
8
Design Guide
I
VLT,N
The rated output current supplied by the frequency
converter.
AC
AWG
U
VLT, MAX
A
The maximum output voltage.
AMA
Control command
I
LIM
Stop the connected motor with LCP and the digital inputs.
°C
Functions are divided into two groups.
DC
Functions in group 1 have higher priority than functions in
D-TYPE
group 2.
EMC
Group 1
ETR
FC
Group 2
g
Hz
hp
Table 1.2 Control Command
kHz
LCP
Motor:
m
f
JOG
mH
The motor frequency when the jog function is activated
mA
(via digital terminals).
ms
f
M
min
The motor frequency.
MCT
f
MAX
nF
The maximum motor frequency.
Nm
f
I
MIN
M,N
The minimum motor frequency.
f
M,N
P
f
M,N
M,N
The rated motor frequency (nameplate data).
U
M,N
PM motor
I
M
PELV
The motor current.
PCB
I
M,N
I
INV
The rated motor current (nameplate data).
RPM
n
Regen
M,N
The rated motor speed (nameplate data).
sec.
n
P
s
M,N
The rated motor power (nameplate data).
T
LIM
V
T
M,N
I
The rated torque (motor).
VLT,MAX
I
VLT,N
U
M
The instantaneous motor voltage.
U
M,N
The rated motor voltage (nameplate data).
η
VLT
The efficiency of the frequency converter is defined as the
ratio between the power output and the power input.
Start-disable command
A stop command belonging to the group 1 control
commands - see this group.
Stop command
See Control Command.
Danfoss A/S © Rev. 06/2014 All rights reserved.
Reset, Coasting stop, Reset and Coasting stop, Quick-
stop, DC braking, Stop and the "Off" key.
Start, Pulse start, Reversing, Start reversing, Jog, and
Freeze output
MG20Z202