EonStor / EonStor DS S12/S16/S24 Series
4. Loosen the screw that secures the control module's ejection levers.
5. Push the ejection levers downwards (indicated by the
controller module will automatically ease out of the controller module bay
6. Insert the new controller module. Carefully push the controller until you feel
the contact resistance when the board edge connectors are engaging the
backplane. Push the ejection levers upward (indicated by the
fasten the retention screw on the ejection levers.
7. Reattach all the cables.
8. For single controller models or when replacing both controllers
simultaneously, power up the system. Check system message
screen, SANWatch, or firmware menu-driven utility. When the replacement
controller is successfully brought online, the
on properly.
9
. For single controller models or replacing both controllers simultaneously,
Power On Status LEDs
145
arrows). The
blue
.
arrows) and
blue
on the LCD
should turn