F-2-36
4) Secure the end of the cable that has temporarily
been fixed in place on the hook of the reader unit
frame.
5) Fully tighten the screws on the cable fixing plate
both at the front and the rear.
6) Detach the mirror positioning tool (FRONT,
REAR).
7) Put the detached parts back on by reversing the
foregoing steps.
2.3.4 When Replacing the
Platen Board Glass
iR5570 / iR6570
Execute the following in service mode:
1)
white
plate
data
FUNCTION> CCD> CCD-ADJ)
2)
ADF
white
level
FUNCTION> CCD> DF-WLVL1/2)
Be sure to perform white plate data adjustment before
[3]
[2]
0009-1984
adjustment
(COPIER>
adjustment
(COPIER>
performing ADF white level adjustment.
2.3.5 When Replacing the
Reading Glass
iR5570 / iR6570
Execute the following in service mode:
1)
ADF
white
(COPIER>FUNCTION>CCD>DF-WLVL1/2)
2.3.6 When Replacing the
Scanning Lamp
iR5570 / iR6570
Execute the following in service mode:
1)
white
plate
data
FUNCTION> CCD> CCD-ADJ)
2)
ADF
white
level
FUNCTION> CCD> DF-WLVL1/2)
Be sure to perform white plate data adjustment before
performing ADF white level adjustment.
2.3.7 When Replacing the
Inverter PCB
iR5570 / iR6570
Execute the following service mode items:
1)
white
plate
data
FUNCTION> CCD> CCD-ADJ)
2)
ADF
white
level
FUNCTION> CCD> DF-WLVL1/2)
Chapter 2
0009-1987
level
adjustment
0009-1989
adjustment
(COPIER>
adjustment
(COPIER>
0009-1990
adjustment
(COPIER>
adjustment
(COPIER>
2-29