3Routing The Grid For The Primary Charging Assembly; Routing The Grid For The Primary Charging Assembly - Canon iR6570 Series Portable Manual

Hide thumbs Also See for iR6570 Series:
Table of Contents

Advertisement

F-2-40
Correct
Grid side
Correct
F-2-41
Make sure of the following:
- The charging wire must not be bent or twisted.
- The charging wire must be fitted in the V-groove of
the charging wire positioner.
9) Attach a cushoin in front of the charg-ing wire.
(This does not apply to the primary charging
assembly.)
10) Mount the shielding plate (left, right).
For other charging assemblies, mount the two lids.
11) Mount the wire cleaner. At this time, pay attention
to make sure that the wire cleaner is oriented
correctly.
12)Wipe the charging wire with lint-free paper
moistened with alcohol.
2.5.3 Routing the Grid for
the Primary Charging
Assembly
iR5570 / iR6570
Wrong
Wrong
0009-5697
1) Loosen the two mounting screws used to secure the
left and right shielding plates in place.
2) Loosen the three mounting screws used to secure
the motor unit in place at the front.
Screws
F-2-42
3) Loosen the mounting screw, and move it in the
direction indicated; then, fix it in place temporarily.
4) Free a length of about 5 cm of charging wire from
the charging wire reel (0.1 mm in diameter), and
form a loop at its end with a diameter of about 2
mm.
Screw
F-2-43
MEMO:
To form a loop, wind the charging wire around a hex
key once, and turn the hex key three to four times;
then, twist the charging wire.
5) Cut the twisted charging wire (excess) with nippers.
6) Hook the loop on stud A.
7) After routing the wire for 31 runs, lead it through
section B, and give it a half turn; then, put it
between the washer and the motor unit, and wind it
once around the mounting screw (clockwise), and
Chapter 2
2-33

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ir5570 series