6Checking The Surface Potential Control System; Checking The Surface Potential Control System - Canon iR6570 Series Portable Manual

Hide thumbs Also See for iR6570 Series:
Table of Contents

Advertisement

Chapter 2
 
Checking the Developing Bias Output
B
Enable potential control: COPIER>
OPTION>BODY>PO-CNT=1
Measure the voltage HVT_DEV_BIAS
_DC during printing of J102A-8 on the
DC controller PCB.
Make the following selections (DC
value of the developing bias):
COPIER>DISPLAY>HV-STS>BIAS.
Covert the indication during printing
(V) into a control voltage with
reference to "Potential Control
Conversion Table."
HVT_DEV-BIAS_DC and 'BIAS'
Check the developing assembly
for leakage; if normal, go to a
check on the transfer output.

2.1.6 Checking the Surface Potential Control System

iR5570 / iR6570
1. Outline
If an image fault occurs, it is necessary to find out whether the cause is in the static image formation block
including the photosensitive drum and the potential control system or if it is caused at time of development or
transfer.
An image fault may be isolated by finding out whether the surface potential is correct using service mode.
2. Disabling the Auto Control Mechanisms
As a means of checking the potential control system, the auto control mechanism may be disabled (hereafter,
non-auto control mode).
If the image fault in question is more or less corrected when the machine is in non-auto control mode, you can
suspect the potential measurement unit and the DC controller PCB as the cause of the fault.
You can also take advantage of non-auto control mode as a tentative remedy when the auto control mechanism
has a fault.
2-12
NO
Is the
deferense between
the actual measurement of
in service mode
± 10%?
YES
Checking the Transfer Output
Is the toner
image on the photosensitive
drum before transfer
normal?
YES
Disable the potential control mechanism
by setting '0' for the following:
COPIER>OPTION>BODY>PO-CNT.
Measure the voltage HVT_TRA during
printing of J102A-12 on the DC
controller PCB.
Make the following selections in service mode
(level of current of transfer charging). Convert
the reading (mA) during printing into a control
voltage based on 8.5 "Potential Control
Conversion Table."
Replace the
Is the
DC controller
difference between
PCB.
the measurement of HVT_
TRANSFER and 'TR' in
service mode
+/- 10%?
YES
Replace the
high-voltage transformer.
Is the problem
corrected?
NO
1) Check the transfer charging assembly for
leakage.
2) Make the following selections in service
mode, and try changing the setting:
COPIER>OPTION>BODY>FUZZY.
3) Try replacing paper.
F-2-12
NO
Replace the
photosensitive
drum.
NO
Replace the
DC controller
PCB.
YES
END