- If you need to dispose of the waste toner, be sure to do so in strict accordance with the regulations imposed by the
local authorities.
- Do not dispose of waste toner in a fire. Doing so may cause an explosion.
5) Clean the copyboard glass and the reading glass.
6) Make test copies.
7) Make sample copies.
8) Check the operation of the leakage breaker.
With the power switch at ON, push the test switch of the leakage breaker to see that it operates normally (i.e., the
breaker switch shifts to the OFF side to cut off the power).
If the leakage beaker fails to operate normally, replace it, and run a check once again.
<Resetting the Breaker>
When you have made the check, turn off the main power switch, and turn on the breaker switch, and then turn the
main power switch back on.
9) Put the sample copies in order, and clean up the area around the machine.
10) Record the final counter reading.
11) Fill out the Service Book, and report to the person in change. Be sure to update the history of checks on the
leakage breaker in the Service Book.