Code
Description
A007
There is a mismatch in version between the
machine control software and the PDL
control software.
B013
The font data is corrupted.
E732
There is a fault in the reader communication.
0001
There is a DDI-S communication error.
E733
There is a fault in the printer communication.
0000
The attempt at communication with the
printer fails at start-up.
0001
There is a DDI-P communication error.
E740
There is a fault in the Ethernet board.
0002
The MAC address is illegal.
E743
There is a fault in the DDI communication.
0000
An SCI error has occurred; the reception
data is faulty; a reception time-out error
has occurred; a SEQ time-out error has
occurred
E744
There is a fault in the language file/boot ROM.
Remedy
- Execute PDL resetting.
- Turn off and then on the main power.
- Execute full formatting and install the
system software.
- Turn off and then on the main power.
- Re-install the system software.
- Execute full formatting and install the
system software.
- Check the communication between the
reader unit and the main controller.
- Check the power supply of the reader
unit. (Check to see if initialization takes
place at start-up.)
- Replace the reader controller PCB,
reader relay PCB, or main controller
PCB.
- Check the connection of the cable
between the DC controller and the main
controller.
- Check the power supply of the printer.
(Check to see if initialization takes place
at start-up.)
- Replace the DC controller PCB or the
main controller PCB.
- Replace the main controller PCB.
- Disconnect and then connect the
connector between the reader unit and the
printer unit.
- Replace the cable, reader controller
PCB, and main controller PCB.