Code
Description
0001
At time of power-on, the communications
IC on the main controller PCB does not
become ready within 3 sec after start-up.
0002
At time of power-on, the communications
IC on the DC controller PCB cannot be
initialized.
E711
There is a fault in the IPC communication.
0001
After power-on, the occurrence of an error
has been written 4 times in 1.5 sec to the
error register of the communications IC on
the main controller PCB.
0002
After power-on, a fault has been detected
by the communications IC on the DC
controller PCB.
E713
There is a fault in the communication with the finisher.
0000
A fault has been detected in the
communications IC on the finisher side.
E717
There is a fault in the communication with the NE controller.
After correcting the fault, be sure to reset the error.
(COPIER>FUNCTION>CLEAR>ERR)
0001
An error has occurred at time of NE
controller start-up.
The NE controller that was connected
before power-off is not connected at
power-on.
0002
There is an IP error while the NE controller
is in operation.
The IPC may have an open circuit or the
IPC communication cannot be recovered.
E719
There is a fault in the coin vendor.
After correcting the fault, be sure to reset the error.
(COPIER>FUNCTION>CLEAR>ERR)
Remedy
- Check the connection of the cable.
- Check the connection of the cable.
- Check the connection of the cable.
- Replace the finisher controller PCB.
- Replace the DC controller PCB.
- Check the connection of the cable.