7Potential Control System Conversion Table; Potential Control System Conversion Table - Canon iR6570 Series Portable Manual

Hide thumbs Also See for iR6570 Series:
Table of Contents

Advertisement

Chapter 2
 
11) Detach the potential sensor checking electrode.
12) Mount the potential sensor.
13) Turn on the main power switch.
14) Enable the potential control mechanism.

2.1.7 Potential Control System Conversion Table

iR5570 / iR6570
Control
(V)
3.00
3.05
3.10
3.15
3.20
3.25
3.30
3.35
3.40
3.45
3.50
3.55
3.60
3.65
3.70
3.75
3.80
3.85
3.90
3.95
2-16
Primar
Developing
y (uA)
bias (V)
1,400
0
1,391
3
1,382
7
1,373
11
1,365
15
1,356
18
1,347
22
1,338
26
1,330
30
1,321
33
1,312
37
1,303
41
1,295
45
1,286
48
1,277
52
1,268
56
1,260
60
1,251
63
1,242
67
1,233
71
T-2-1
Pre-
Transfer
transfer
(uA)
(uA)
0
440
-2
437
-4
434
-6
431
-8
429
-10
426
-12
426
-14
420
-16
418
-18
415
-20
412
-22
409
-24
407
-26
404
-28
401
-30
398
-33
396
-35
393
-37
390
-39
387
0008-7915
Separation
(uA)
100
96
92
88
85
81
77
73
70
66
62
58
55
51
47
43
40
36
32
28