Chrysler Concorde 1993 Service Manual page 188

Table of Contents

Advertisement

5 - 94
ANTI-LOCK BRAKE SYSTEM
Fig. 6 Brake Fluid Tube Connections At (HCU)
Fig. 7 (HCU) To Inner Fender Mounting Bolt
Fig. 8 (HCU) To Frame Rail Mounting Bolts
INSTALL
(1) Install (HCU) and bracket as an assembly back
on left frame rail of vehicle. Install but do not
tighten the 2 (HCU) bracket to frame rail mounting
bolts (Fig. 8). Install the (HCU) bracket to inner
fender mounting bolt (Fig. 7). Torque the 2 (HCU)
bracket to frame rail attaching bolts to 19 N¼m (14
ft. lbs.). The torque bracket to inner fender bolt to 2
N¼m (18 in. lbs.).
(2) Connect the 2 brake fluid supply tubes from
the master cylinder onto the inlet ports of the (HCU)
(Fig. 9). Connect the 2 brake fluid output tubes to
the ports on the (HCU) valve block (Fig. 9). Torque
all 4 brake tube fitting nuts to 19 N¼m (14 ft. lbs.).
Fig. 9 Brake Fluid Tube Connections At (HCU)
(3) Connect the 2 rear brake tubes onto the propor-
tioning valves located on valve block of hydraulic as-
sembly (Fig. 10). Torque the 2 brake tube fitting
nuts at proportioning valves to 19 N¼m (14 ft. lbs.).
(4) Remove plug from end of brake fluid supply
hose going to reservoir at (HCU). Connect supply
hose on (HCU) reservoir nipple and install hose
clamp on hose. Be sure clamp is past bead on nipple
of (HCU) fluid reservoir.
Fig. 10 Brake Tube Connections At Proportioning
(5) VERIFY THAT THE VEHICLE IGNITION
IS OFF BEFORE CONNECTING THE 37 WAY
CONNECTOR. Connect the wiring harness 37 way
Valves