For example, if a calling station starts an ALE call containing data through an HF
network that has its privacy mode set to Plain, and the called station determines that
the address is valid in HF networks with the privacy mode set to Group or Plain, then
it selects the HF network with the privacy mode set to Plain on which to establish the
link. Any data communications within this link use the basic 64 ASCII subset of
characters.
However, if the called station determines that the address is available in an HF
network with the privacy mode set to Group, it selects this HF network on which to
establish the link. Data communications within this link are only successful if the
calling station uses the same password as the HF network with the privacy mode set
to Group at the called station.
If a calling station starts an ALE call without data, the called station determines in
which HF networks the address is valid, selects an HF network with the lowest privacy
mode available, then establishes the link. Data communications may proceed as per
the privacy modes of the selected calling and called HF networks.
Privacy password
The Privacy Password entry applies to Codan Selcall and ALE/CALM HF
networks where the privacy mode is set to Group. The privacy password is defined
arbitrarily by the system administrator or user, and programmed into the transceiver.
The password can be up to 15 characters long.
CAUTION:
Rx only
The Rx Only entry sets whether the address set for this HF network is used for
receiving calls only, or can be used for sending calls also.
146
Changing this password must be managed across all transceivers using
this HF network.