Parameters - Agatec EZDigPro User & Calibration Manual

Table of Contents

Advertisement

[usage]

Parameters

PARAMETERS
Caution:
Changing values in the parameters has a big effect on the performance of the system. Only access this menu area after
you've carefully read the following section!
PARAMETERS
PARAMETERS
LasTimOut
LasTimOut
DoubleLS
DoubleLS
Filter
Filter
DeadBaF
0.010
DeadBaF
0.010
DeadBaM
0.025
DeadBaM
0.025
DeadBaC
0.050
DeadBaC
0.050
LedDeUp
0.500
LedDeUp
0.500
LedDeDw
-0.100
LedDeDw
-0.100
LedReGr
0.050
LedReGr
0.050
LedReRe
0.100
LedReRe
0.100
^^^^^^^^^^^^^^^^
^^^^^^^^^^^^^^^^
LasTimOut
Laser activation time: number of tenths of a second the system
waits for a laser catch, before it automatically returns to the
previous screen. (150 is 15 seconds).
DoubleLS
Enable/Disable (ON/OFF) the second static laser catch of the
laser beam in laser enabled mode. See details in "[usage]
Laser Function."
Filter
Depth and Reach visualized values filter.
Higher filter: more stable reading but slower response time.
DeadBaF / DeadBaM / DeadBaC
The defaults for the 3 dead bands (fine, medium, or coarse)
are listed in "Usage - Dead Band Selection" on page 74. You
can change the defaults in this Parameters screen.
LedDeUp / LedDeDw / LedReGr / LedReRe
Depth and reach indication limit of the Remote Display.
EZDigPro
150
150
ON
ON
1
1
LedDeUp
Dead Band
LedDeDw
- 78 -
LedReRe
LedReGr
User & Calibration Manual