Remove Coin Drop Mechanism - Maytag MFR Series Service Manual

Hide thumbs Also See for MFR Series:
Table of Contents

Advertisement

Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
1.
Raise the top of the washer (See page 4-2).
2.
Remove two 5/16" hex head screws from
the rear of the coin drop mechanism inside
the cabinet.
3.
It may be necessary to tap the mechanism
to get it to come loose.
4.
Remove the optical switch by pushing the
coin drop mechanism out a bit through the
front to access and remove the number one
star head screw securing the optical switch.
Two 5/16" Hex
Head Screws
1 Star Head
Screw

ReMOve COin DROp MeCHaniSM

5.
To clean the coin drop mechanism, remove
the top clip. Open and remove the left side.
6.
Remove any dirt or sediment inside halves.
7.
Lubricate just the coin return plunger with
white lube or grease.
8.
Reassemble the left side piece. Insert the
bottom edge and it drops into place.
Lubrication
Point
9.
Put the clip in approximately the center of
the groove.
10.
Adjust the top clip if necessary to make
sure there is good smooth action of the coin
return button.
Coin Return
Plunger
4-9
Bottom Edge
Of Left Side
Top Clip