ReMOve THe BaSkeT - MFR40 & 50
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
1.
Remove the cabinet (See page 5-1).
2.
Disconnect the overflow tube at the "T"
fitting.
3.
Remove the 24 nuts and bolts connecting
the back-plate to the outer tub.
Overflow
"T" Fitting
4.
Mark the bolt holes that have tabs on them
for wiring harness wire ties.
Marks
5.
Remove the bolt from each side that
secures the back of the tub to the tub
support with double nuts and a washer.
Double Nuts
& Washer
Bolt
6.
Spread the rear ring using two screwdrivers
to release the silicone.
6-24
Wire Tie Tab