FOR SERVICE TECHNICIAN ONLY - DO NOT REMOVE OR DESTROY
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or
electrical shock.
IMPORTANT
Electrostatic Discharge (ESD)
Sensitive Electronics
ESD problems are present everywhere. ESD may damage or
weaken the electronic control assembly. The new control
assembly may appear to work well after repair is finished, but
failure may occur at a later date due to ESD stress.
Use an anti-static wrist strap. Connect wrist strap to green
ground connection point or unpainted metal in the
appliance
-OR-
Touch your finger repeatedly to a green ground connection
point or unpainted metal in the appliance.
Before removing the part from its package, touch the
anti-static bag to a green ground connection point or
unpainted metal in the appliance.
Avoid touching electronic parts or terminal contacts; handle
electronic control assembly by edges only.
When repackaging failed electronic control assembly in
anti-static bag, observe above instructions.
DIAGNOSTIC GUIDE
Before servicing, check the following:
Make sure there is power at the wall outlet.
Has a household fuse blown or circuit breaker tripped? Time
delay fuse?
Are both hot and cold water faucets open and water supply
hoses unobstructed?
All tests/checks should be made with a VOM or DVM having a
sensitivity of 20,000 ohms per volt DC or greater.
Check all connections before replacing components. Look for
broken or loose wires, failed terminals, or wires not pressed
into connections far enough.
The most common cause for control failure is corrosion on
connectors. Therefore, disconnecting and reconnecting wires
will be necessary throughout test procedures.
Connectors: Look at top of connector. Check for broken or
loose wires. Check for wires not pressed into connector far
enough to engage metal barbs.
Resistance checks must be made with power cord unplugged
from outlet, and with wiring harness or connectors
disconnected.
PART NO. 4619 702 21681 / 8182208
POUR LE TECHNICIEN SEULEMENT - NE PAS ENLEVER NI DÉTRUIRE
AVERTISSEMENT
Déconnecter la source de courant électrique
avant l'entretien.
Replacer pièces et panneaux avant de faire
la remise en marche.
Le non-respect de ces instructions peut
causer un décès ou un choc électrique.
Circuits électroniques sensibles
aux décharges électrostatiques
Le risque de décharge électrostatique est permanent. Une
décharge électrostatique peut endommager ou affaiblir les
composants électroniques. La nouvelle carte peut donner
l'impression qu'elle fonctionne correctement après la
réparation, mais une décharge électrostatique peut lui avoir
fait subir des dommages qui provoqueront une défaillance
plus tard.
Utiliser un bracelet de décharge électrostatique. Connecter
le bracelet à la vis verte de liaison à la terre ou sur une
surface métallique non peinte de l'appareil
-OU-
Toucher plusieurs fois du doigt la vis verte de liaison à la
terre ou une surface métallique non peinte de l'appareil.
Avant de retirer la pièce de son sachet, placer le sachet
antistatique en contact avec la vis verte de liaison à la terre
ou une surface métallique non peinte de l'appareil.
Éviter de toucher les composants électroniques ou les
broches de contact; tenir la carte de circuits électroniques
par les bords seulement lors des manipulations.
Lors du réemballage d'une carte de circuits électroniques
défaillante dans le sachet antistatique, appliquer les mêmes
instructions.
GUIDE DE DIAGNOSTIC
Avant d'entreprendre une réparation, contrôler ce qui suit :
Vérifier que la prise de courant est alimentée.
Fusible grillé ou disjoncteur ouvert? Fusible temporisé grillé?
Robinets d'eau chaude et d'eau froide ouverts et tuyaux
d'arrivée d'eau exempts d'obstruction?
Utiliser pour tous les contrôles un voltmètre ou autre instrument
dont la résistance interne est de 20 000 ohms par volt CC
ou plus.
Contrôler toutes les connexions avant de remplacer un
composant. Rechercher des fils brisés ou mal connectés, ou
des bornes ou cosses de connexion détériorées.
La corrosion des pièces de connexion constitue la principale
cause de défaillance du système de commande. Par
conséquent il sera nécessaire de débrancher/rebrancher des
conducteurs dans toutes les opérations de test.
Connecteurs : Examiner le sommet d'un connecteur;
rechercher des fils brisés ou mal connectés; rechercher
également des cosses mal branchées.
Lors de toute mesure de résistance, vérifier que le cordon
d'alimentation est débranché de la prise de courant, et que le
faisceau de câblage ou le connecteur est débranché.
PAGE 1
Risque de choc électrique
IMPORTANT
PIÈCE N o 4619 702 21681 / 8182208

Advertisement

Table of Contents
loading

Summary of Contents for Maytag mfw9600sq0

  • Page 1 FOR SERVICE TECHNICIAN ONLY - DO NOT REMOVE OR DESTROY POUR LE TECHNICIEN SEULEMENT - NE PAS ENLEVER NI DÉTRUIRE AVERTISSEMENT WARNING Risque de choc électrique Electrical Shock Hazard Déconnecter la source de courant électrique Disconnect power before servicing. avant l’entretien. Replace all parts and panels before operating.
  • Page 2: Failure/Error Display Codes

    FOR SERVICE TECHNICIAN ONLY - DO NOT REMOVE OR DESTROY POUR LE TECHNICIEN SEULEMENT - NE PAS ENLEVER NI DÉTRUIRE FAILURE/ERROR DISPLAY CODES CODES AFFICHÉS POUR DÉFAILLANCE/ERREUR Display EXPLANATION AND RECOMMENDED PROCEDURE DESCRIPTION ET MÉTHODE DE RÉPARATION RECOMMANDÉE Affichage NO WATER DETECTED ENTERING MACHINE AUCUNE DÉTECTION D’ENTRÉE D’EAU DANS LA MACHINE OR PRESSURE SWITCH TRIP NOT DETECTED.
  • Page 3 FOR SERVICE TECHNICIAN ONLY - DO NOT REMOVE OR DESTROY POUR LE TECHNICIEN SEULEMENT - NE PAS ENLEVER NI DÉTRUIRE Display EXPLANATION AND RECOMMENDED PROCEDURE DESCRIPTION ET MÉTHODE DE RÉPARATION RECOMMANDÉE Affichage WATER TEMPERATURE SENSOR ERROR CAPTEUR DE TEMPÉRATURE DE L’EAU – ERREUR If during the water heating step in the wash cycle, the water Si durant l’étape de chauffage de l’eau du programme de lavage la valeur produite par le temperature sensor (NTC) value is out of range, the “F/05”...
  • Page 4 FOR SERVICE TECHNICIAN ONLY - DO NOT REMOVE OR DESTROY POUR LE TECHNICIEN SEULEMENT - NE PAS ENLEVER NI DÉTRUIRE Display EXPLANATION AND RECOMMENDED PROCEDURE DESCRIPTION ET MÉTHODE DE RÉPARATION RECOMMANDÉE Affichage OVERFLOW CONDITION DÉBORDEMENT If the overflow contact on the pressure switch is closed for more than Si le contacteur “débordement”...
  • Page 5 FOR SERVICE TECHNICIAN ONLY - DO NOT REMOVE OR DESTROY POUR LE TECHNICIEN SEULEMENT - NE PAS ENLEVER NI DÉTRUIRE Display EXPLANATION AND RECOMMENDED PROCEDURE DESCRIPTION ET MÉTHODE DE RÉPARATION RECOMMANDÉE Affichage DISPENSER CIRCUIT ERROR SYSTÈME DE DISTRIBUTION DE PRODUITS – ERREUR If the dispenser motor is not able to be driven to its proper position.
  • Page 6 FOR SERVICE TECHNICIAN ONLY - DO NOT REMOVE OR DESTROY POUR LE TECHNICIEN SEULEMENT - NE PAS ENLEVER NI DÉTRUIRE Display EXPLANATION AND RECOMMENDED PROCEDURE DESCRIPTION ET MÉTHODE DE RÉPARATION RECOMMANDÉE Affichage DOOR UNLOCK ERROR DÉVERROUILLAGE PORTE – ERREUR A Door Unlock Error occurs if the door cannot be unlocked. It will try to Le code d’erreur “Déverrouillage porte”...
  • Page 7: Diagnostic Test

    FOR SERVICE TECHNICIAN ONLY - DO NOT REMOVE OR DESTROY POUR LE TECHNICIEN SEULEMENT - NE PAS ENLEVER NI DÉTRUIRE DIAGNOSTIC TEST TEST DE DIAGNOSTIC The washer must be empty and the control must be in the La machine doit être vide et avant d’exécuter la séquence de state before pressing the touch-pad sequence to start the test.
  • Page 8 FOR SERVICE TECHNICIAN ONLY - DO NOT REMOVE OR DESTROY POUR LE TECHNICIEN SEULEMENT - NE PAS ENLEVER NI DÉTRUIRE Be sure to perform the Diagnostic Tests before replacing the Ne pas oublier d'exécuter les tests de diagnostic avant de system components.
  • Page 9: Control Board Removal Or Replacement

    FOR SERVICE TECHNICIAN ONLY - DO NOT REMOVE OR DESTROY POUR LE TECHNICIEN SEULEMENT - NE PAS ENLEVER NI DÉTRUIRE CONTROL BOARD REMOVAL OR REPLACEMENT DÉPOSE ET REMPLACEMENT DE LA CARTE DES CIRCUITS DE COMMANDE IMPORTANT: Electrostatic (static electricity) discharge may cause damage to electronic control assemblies.
  • Page 10: Wiring Diagram

    FOR SERVICE TECHNICIAN ONLY - DO NOT REMOVE OR DESTROY POUR LE TECHNICIEN SEULEMENT - NE PAS ENLEVER NI DÉTRUIRE WIRING DIAGRAM SCHÉMA DE CÂBLAGE INTERFERENCE FILTER Filtre pour interférences DRIVE MOTOR Terre/Masse Moteur d’entraînement M13.3 IF2.1 IN/OUT Entrée/Sortie M13.2 IF2.1 M13.1 OA8.1...
  • Page 11: Troubleshooting Guide

    FOR SERVICE TECHNICIAN ONLY - DO NOT REMOVE OR DESTROY POUR LE TECHNICIEN SEULEMENT - NE PAS ENLEVER NI DÉTRUIRE TROUBLESHOOTING GUIDE GUIDE DE DIAGNOSTIC POSSIBLE CAUSE/TEST CAUSES POSSIBLES/TEST PROBLEM NOTE: Possible Cause/Tests must be performed in the NOTE : Pour chaque problème, on doit exécuter les opérations “Causes Problème sequence shown for each problem.
  • Page 12 FOR SERVICE TECHNICIAN ONLY - DO NOT REMOVE OR DESTROY POUR LE TECHNICIEN SEULEMENT - NE PAS ENLEVER NI DÉTRUIRE TROUBLESHOOTING GUIDE GUIDE DE DIAGNOSTIC POSSIBLE CAUSE/TEST CAUSES POSSIBLES/TEST PROBLEM NOTE: Possible Cause/Tests must be performed in the NOTE : Pour chaque problème, on doit exécuter les opérations “Causes Problème sequence shown for each problem.

Table of Contents