ReMOve TeRMinal BlOCk
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
1.
Raise the top of the washer (See page 4-2).
2.
Disconnect the wires from the terminal
block.
3.
Remove the 8mm bolt that secures the
terminal block cover on the rear of the
washer.
4.
Remove the two 12mm hex nuts that
secure the terminal block to the retaining
bracket. Reach under the top of the washer
to secure the screws with a flat blade
screwdriver while removing the hex nuts.
2 Hex Nuts
2 Flat Blade
Screws
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
1.
Remove the hex head screws from the back
panel.
2.
Remove the back panel from the washer.
Retaining
Bracket
4-28
ReMOve BaCk panel
Electrical Shock Hazard