Remove Tub From Frame - Mfr40 & 50 (All Other Models Are Similar) - Maytag MFR Series Service Manual

Hide thumbs Also See for MFR Series:
Table of Contents

Advertisement

ReMOve TuB FROM FRaMe - MFR40 & 50
(all OTHeR MODelS aRe SiMilaR)
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
excessive Weight Hazard
use two people to move or install
heavy parts.
Failure to do so can result in back or
other injury.
1.
Remove the basket (See page 6-24).
2.
Remove the 13mm hex nut and washer
from the bolt attaching the strap to frame.
3.
Pull bolt to release strap from around tub.
Tub Strap
Chemical Dispenser
Connecting Hose
13mm
Hex Nut
Rubber
Seal Strip
6-34
4.
Loosen the clamp that connects the hose
from the tub to the drain valve.
5.
Remove air hose from hanger on the tub.
Drain Hose
Clamp
6.
Using 2 people, lift tub off of the tub support.
7.
If replacing a damaged tub with a new tub,
remove the chemical dispenser connecting
hose from the top side and install on the
new tub.
8.
Remove the rubber seal strip from around
the edge of the tub and secure it on the new
tub.
Air Hose
Hanger