Convert Coin Washer To Simple Opl - Maytag MFR Series Service Manual

Hide thumbs Also See for MFR Series:
Table of Contents

Advertisement

COnveRT COin WaSHeR TO SiMple Opl

Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
1.
For Service Kit parts list: (See page 1-13).
2.
Remove the coin box from the washer
3.
Install coin box cover in place of coin box
(Part 1).
4.
Remove the coin drop (See page 4-9).
5.
Install coin drop cover plate assembly
(Part 2) and central stop wiring (Part 7) in
place of the coin drop.
6.
Make sure to use plastic washers
(Part 6), washers (Part 4,5), and nuts
(Part 3) for connecting the coin drop cover
plate assembly. Sticker must be tightened
very well. Avoid over tighting welded bolts.
7.
Disconnect interconnection from main wiring
and connect the central stop wiring (Part 7).
Secure the wiring with wire ties.
8.
Disconnect the wire connections from the
coin vault switch and interconnect this by
AMP 155914 (Part 9). Secure the wiring
with wire ties.
2-4

Advertisement

Table of Contents
loading

Table of Contents