Assigning Certain Functions To Analog Outputs - Siemens Sinamics G120 CU240E Operating Instructions Manual

Table of Contents

Advertisement

Functions
5.9 Evaluating the frequency inverter status
5.9.2

Assigning certain functions to analog outputs

Assigning specific functions to analog outputs
Two analog outputs are available, which can be parameterized to display a multitude of
variables, e.g. the actual speed, the actual output voltage or the actual output current.
Table 5- 34
Terminal No., significance
12
13
26
27
Table 5- 35
Terminal No., significance
12
13
26
27
The analog outputs can also be interconnected with all connector outputs. A list of the
connector outputs is provided in the List Manual.
126
Factory setting of the analog outputs
AO0+
Analog input 0
AO0-
AO1+
Analog input 1
AO1-
Changing the analog output settings
AO0+
Analog input 0
AO0-
AO1+
Analog input 1
AO1-
Function
Actual speed
Actual speed
Parameter
Description
P0771
Possible values for P0771, Ind 0 and Ind 1:
[Ind 0]
21:CO: Actual frequency (factory setting; scaled
corresponding to P2000)
P0771
24:CO: Actual output frequency (scaled
[Ind 1]
corresponding to P2000)
25:CO: Actual output voltage (scaled
corresponding to P2001)
26:CO: Actual value of the DC link voltage (scaled
corresponding to P2001)
27:CO: output current (scaled in line with P2002)
Frequency inverter
Operating Instructions, 08.10. 2008, t.b.d.