Table 5- 28
Parameter
P0003 = 2
P0400 = ...
P0408 = ...
P0410 = ...
P0491 = ...
P0492 = ...
P0494 = ...
P1442 = ...
P1300 = 21
or
P1300 = 23
Frequency inverter
Operating Instructions, 08.10. 2008, t.b.d.
The most important speed encoder parameters
Description
Extended access to the inverter functions
Encoder type
0: Encoder signal is not evaluated
2: Encoder with pulse tracks A and B without zero pulse
12: Encoder with pulse tracks A, B and zero pulse
Encoder pulses per revolution
Inverts the encoder signal
0: The encoder signal is not influenced
1: The encoder signal is inverted
Response when the speed signal is lost
0: Motor is shut down with fault message F0090
1: Alarm and switch to SLVC, if in SVC
Permissible speed difference for monitoring the encoder signal (F0090)
Delayed response when the speed signal is lost
Filter time for the speed encoder actual value
Control type: Vector control with speed encoder
Functions
5.7 Closed-loop control