Technical Data Of The Cu240E - Siemens Sinamics G120 CU240E Operating Instructions Manual

Table of Contents

Advertisement

Technical data

8.2 Technical data of the CU240E

8.2
Technical data of the CU240E
CU240E
Feature
Operating voltage
Heat loss
Setpoint resolution
Digital inputs
(dependent on the CU
type)
Analog inputs
Digital outputs
Analog outputs
Weight
224
Data
Supply from the Power Module
< 40W
0.01 Hz
6, floating; PNP/NPN switchable
Low < 5 V, High > 10 V, maximum input voltage 30 V, 5.5 mA
2, with 10-bit resolution
AI0: 0 V to 10 V, 0 mA to 20 mA and -10 V to+10 V
AI1: 0 V to 10 V and 0 mA to 20 mA
Both analog inputs can also be configured as digital inputs
3 relay outputs, 30 V DC / max. 0.5 A for a resistive load
2
AO0: 0 V to 10 V or 0 mA to 20 mA
AO1: 0 mA to 20 mA
0.21 kg
Frequency inverter
Operating Instructions, 08.10. 2008, t.b.d.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics g120 cu240s pn-fSinamics g120 cu240s dpSinamics g120 cu240s pnSinamics g120 cu240sSinamics g120 cu240s dp-f

Table of Contents