Analog Inputs And Outputs - Siemens SIMOTION D4 5 Series Manual

Table of Contents

Advertisement

Supplementary system components
6.3 TB30 terminal board
6.3.3.5

Analog inputs and outputs

Table 6- 7
Terminal block X482
Terminal
1
2
3
4
5
6
7
8
Table 6- 8
Features
Connectable cable types
- Rigid
- Flexible
- Flexible, with end sleeve without plastic sleeve
- AWG/kcmil
Stripped length
Tool
Note
An open input is interpreted as approximately "0 V".
The power supply of the analog inputs/outputs of the TB30 is via the option slot of the D4x5
Control Unit and not via X424.
The shield is connected to the Control Unit. For further information, see
Commissioning and Hardware Installation Manual, "Connection" chapter.
CAUTION
The common-mode range must not be infringed.
The analog differential voltage signals can have a maximum offset voltage of ±30 V with
respect to the ground potential. If the range is infringed, incorrect results may occur during
analog/digital conversion.
86
Designation
1)
AI 0+
AI 0-
AI 1+
AI 1-
AO 0+
AO 0-
AO 1+
AO 1-
X482 wiring
Technical specifications
Analog inputs (AI):
- Voltage: -10 V to +10 V
- Internal resistance: 65 kΩ
- Resolution: 13 bits + sign
Analog outputs (AO):
- Voltage range: -10 V to +10 V
- Load current: Max. -3 mA to +3 mA
- Resolution: 11 bits + sign
- Continuous short-circuit-proof
Type
Conductor cross-sections
0.14 mm
to 0.5 mm
2
0.14 mm
to 0.5 mm
2
0.25 mm
to 0.5 mm
2
26 to 20
8 to 9 mm
Screwdriver 0.4 x 2.0 mm
2
2
2
SIMOTION D4x5
SIMOTION D4x5
Manual, 02/2012