Table 7-106 Input image of analog inputs (excerpt)
Byte
Bit7
m+0
0
m+1
Error bit
7.7.4.3

Assigning parameters to the analog inputs / outputs

Operating mode
Parameters are assigned to the operating mode via the m+0 byte (Analog Control Byte 0) of
the output image of the analog outputs:
Byte
m+0
m+1
m+2
m+3
The reserved bits must be preassigned with the value "0".
The operating mode is set to "no operating mode" during power-up, as soon as a valid setting
is made this will be applied and will subsequently no longer be reset. If a reset is initiated by
the user, this is interpreted as an error.
Type of control
The control type must be specified in the Analog Control Byte m+1 (bit 0), so that the 16 bit
input and output values from and for the analog module are correctly interpreted by the control.
In the SINUMERIK 828D control, the value "1" must be entered.
Note
The control type must be set prior to the operating mode so that the first set of user data is
not misinterpreted. In addition to this, the Analog Control Byte m+0 / m+1 must only be
accessed byte by byte.
Assigning parameters to the analog inputs
The analog inputs (AI) can be operated in the following operating modes:
Operating mode 1st channel
No operating mode
Voltage measurement
PPU
Manual, 01/2014, 6FC5397-2DP40-3BA3
Bit6
Bit5
0
0
0
0
Bit7
Bit6
AO
AO
(channel
(channel
4)
4)
Bit4
Bit3
0
0
0
0
Bit5
Bit4
Bit3
AO
AO
AI
(channel
(channel
(channel
3)
3)
2)
Reserved
Reserved
Reserved
Connectable components
7.7 PP 72/48D 2/2A PN
Bit3
Bit1
0
0
0
0
Bit3
Bit1
AI
AI
(channel
(channel
2)
1)
Bit 1
Bit 0
0
0
0
1
Bit0
0
0
Bit0
AI
(channel
1)
Data
format
207