Siemens Sinamics G120 CU240E Operating Instructions Manual page 57

Table of Contents

Advertisement

Terminal
Abbreviation
3
AI0+
AI0
4
AI0-
10
AI1+
AI1
11
AI1-
Terminal
Abbreviation
12
AO0+
AO0
13
AO0-
26
AO1+
AO1
27
AO1-
Terminal
Function
70
Channel A -
non-inverting
71
Channel A -
inverting
72
Channel B -
non-inverting
73
Channel B -
inverting
74
Zero pulse -
non-inverting
75
Zero pulse -
inverting
Terminal
Abbreviation
14
PTC+
15
PTC-
Frequency inverter
Operating Instructions, 08.10. 2008, t.b.d.
Analog inputs
Parameter
Factory setting
P0756 [0]
0
P0756 [1]
0
Analog outputs
Parameter
Factory setting
P0771[0]
21
P0771[1]
21
Encoder interface (encoder)
Parameter
Factory setting
P0400
0
PTC/KTY84 interface
Parameter
Factory setting
P0601
0
4.4 Commissioning with factory settings
Meaning of the factory setting
Set unipolar voltage input
0 V ... +10 V DC
in addition to parameterizing DIP switch on CU housing.
Set unipolar voltage input
0 V ... +10 V DC
in addition to parameterizing DIP switch on CU housing.
Meaning of the factory setting
Frequency on the inverter output;
analog output 0 can be switched from current output to
voltage output by means of P0776
Frequency on the inverter output;
analog output 1 is current output only
Meaning of the factory setting
Evaluation of the speed encoder is blocked
Meaning of the factory setting
Evaluation of the motor temperature sensor is blocked
Commissioning
57