Bico Technology: Example - Siemens Sinamics G120 CU240E Operating Instructions Manual

Table of Contents

Advertisement

1.4 Extended adaptation options using BICO parameters (parameterization for advanced level personnel)
1.4.2

BICO technology: example

Example: Shifting a basic PLC functionality into the frequency inverter
A conveyor system is to be configured in such a way that it can only start when two signals
are present simultaneously. These could be the following signals, for example:
● The oil pump is running (the required pressure level is not reached, however, until after
● The protective door is closed
The task is realized by inserting free blocks between the digital input 0 and the internal ON
command for the motor and interconnecting them.
DI 0
DI 1
Figure 1-4
Parameter
P0003 = 3
P0700 = 2
P0701 (e.g.) = 99
P0702 (e.g.) = 99
P2800 = 1
P2801 [In000] = 1
P2802 [In000] = 1
P2850 = 5.0
P2849 = r0722.0
P2810 [In000] = r2852
P2810 [In001] = r0722.1
P0840 = r2811
Frequency inverter
Operating Instructions, 08.10. 2008, t.b.d.
five seconds)
P2850 = 5,0 [s]
T
P2849
r0722.0
Index [0]
Timer
r0722.1
Example: Signal interconnection for interlock
Description
Enable expert access to parameters
Select the command source
Enable/"open" digital input 0 (DI0) for BICO parameterization
Enable/"open" digital input 1 (DI1) for BICO parameterization
Group enable all freely-programmable function blocks (FFB)
Individual enable of the AND function block
Individual enable of the TIMER function block
Set the TIMER delay time: 5 seconds
Connect the status of DI0 to the TIMER input
r0722.0 = Parameter that displays the status of digital input 0.
Connect the TIMER output to the 1st input of the AND
Connect the status of DI1 to the 2nd AND input
r0722.1 = Parameter that displays the status of digital input 1.
Connect the AND output to the control command ON/OFF1
P2800
0
r2852
P2810
Index [0]
Index [1]
P2801[0]
P0840
&
r2811
Index [0]
Introduction
ON/
OFF1
19

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics g120 cu240s pn-fSinamics g120 cu240s dpSinamics g120 cu240s pnSinamics g120 cu240sSinamics g120 cu240s dp-f

Table of Contents