11.2

AIR TEST

GA 5000EA
Switch off the atomizing and shaping air, switch on control air.
1. 0.4 MPa; 4 bar; 58 psi: The air valve must switch on correctly.
2. 0.8 MPa; 8 bar; 116 psi: Test for air seal.
3. Switch off control air: The air valve must switch off correctly.
11.3

PRODUCT PRESSURE TEST

Connect the product hose to the spray gun.
Test the seal of the spray gun with suitable medium (e.g., fl ushing agent or Marcol 52) and
a maximum pressure of 0.8 MPa; 8 bar; 116 psi. Increase the pressure gradually while doing
so.
Observe the following gun components:
Product connection, nozzle body, product valve (no post-spraying).
Exploding gas / air mixture!
Danger to life from fl ying parts and burns.
11.4

TEST OF SPRAY PATTERN

Check spray pattern in accordance with Chapter 7.3.1
ORDER NUMBER DOC2360924
DANGER
Never spray into a closed tank.
Ground the tank.