Configuring ILOM IP Addresses Manually

6.5.1 Using a Serial Connection

Connect to the ILOM using a serial connection, as described in
1.
ILOM via a Serial
Run the following commands at the ILOM command prompt:
2.
cd /SP/network
set pendingipdiscovery=static
set pendingipaddress=<ip_address>
set pendingipnetmask=<ip_netmask>
set pendingipgateway=<ip_gateway>
set commitpending=true

6.5.2 Using the Ethernet Connection

Connect to the ILOM using the Ethernet connection, as described in
1.
ILOM via the
Run the following commands at the ILOM command prompt:
2.
cd /SP/network
set pendingipdiscovery=static
set pendingipaddress=<ip_address>
set pendingipnetmask=<ip_netmask>
set pendingipgateway=<ip_gateway>
set commitpending=true

6.5.3 Using ipmitool Commands When SP Network Information Is Lost

If the service processor (SP) network information gets lost, you can use an SSH shell
to connect to the
the appropriate
example:
/usr/sbin/ipmitool sunoem cli 'set /SP/users/root password=somepasswd' somepasswd
This example resets the ILOM root password.
Connection.
Network.
interface of the operating system on the Exalytics host and run
ETH0
commands to reconfigure network settings, as in the following
ipmitool
Chapter 6
Configuring Network Access
Connecting to
Connecting to
6-5