Configure Calculation Speed (Response Time); Configure Alarm Handling - Emerson Micro Motion 2700 Configuration And Use Manual

Transmitters with analog outputs
Hide thumbs Also See for Micro Motion 2700:
Table of Contents

Advertisement

5.4.2

Configure Calculation Speed (Response Time)

Display
ProLink II
ProLink III
Field Communicator Not available
Overview
Calculation Speed is used to apply a different algorithm to the calculation of process variables
from the raw process data. Calculation Speed = Special produces faster and "noisier" response
to changes in the process.
In ProLink II, Calculation Speed is called Response Time.
Restriction
Calculation Speed is available only on systems with the enhanced core processor.
Tip
You can use Calculation Speed = Special with either setting of Update Rate. The parameters control
different aspects of flowmeter processing.
Procedure
Set Calculation Speed as desired.
Option
Normal
Special
5.5

Configure alarm handling

The alarm handling parameters control the transmitter's response to process and device
conditions.
Alarm handling parameters include:
Configuration and Use Manual
Not available
ProLink > Configuration > Device > Response Time
Device Tools > Configuration > Process Measurement > Response > Calculation Speed
Description
Transmitter calculates process variables at the standard speed.
Transmitter calculates process variables at a faster speed.
Fault Timeout
Status Alarm Severity
Configure device options and preferences