Emerson Micro Motion 2700 Configuration And Use Manual page 109

Transmitters with analog outputs
Hide thumbs Also See for Micro Motion 2700:
Table of Contents

Advertisement

Procedure
Set mA Output Process Variable as desired.
The default setting is Mass Flow Rate.
Options for mA Output Process Variable
The transmitter provides a basic set of options for mA Output Process Variable, plus several
application-specific options. Different communications tools may use different labels for
the options.
Table 6-1:
Options for mA Output Process Variable
Process variable
Display
Standard
MFLOW
Mass flow rate
VFLOW
Volume flow rate
GSV F
Gas standard volume
flow rate
TEMP
Temperature
DENS
Density
EXT P
External pressure
EXT T
External temperature
DGAIN
Drive gain
Petroleum measurement
TCDEN
Temperature-correc-
ted density
TCVOL
Temperature-correc-
ted (standard) volume
flow rate
AVE D
Average corrected
density
AVE T
Average temperature
Configuration and Use Manual
If you plan to configure an output to report a concentration measurement process
variable, ensure that the concentration measurement application is configured so
that the desired variable is available.
If you are using the HART variables, be aware that changing the configuration of mA
Output Process Variable will change the configuration of the HART Primary Variable
(PV).
If you have configured Display Variable 1 to track mA Output Process Variable, be aware
that changing the configuration of mA Output Process Variable will change the contents
of Display Variable 1.
ProLink II
Mass Flow Rate
Volume Flow Rate
Gas Std Vol Flow Rate
Temperature
Density
External Pressure
External Temperature
Drive Gain
API: Temp Corrected
Density
API: Temp Corrected Vol-
ume Flow
API: Avg Density
API: Avg Temperature
Integrate the meter with the control system
Label
ProLink III
Mass Flow Rate
Volume Flow Rate
Gas Standard Volume
Flow Rate
Temperature
Density
External Pressure
External Temperature
Drive Gain
Density at Reference
Temperature
Volume Flow Rate at Ref-
erence Temperature
Average Density
Average Temperature
Field Communicator
Mass flo
Vol flo
Gas vol flo
Temp
Dens
External pres
External temp
Driv signl
TC Dens
TC Vol
TC Avg Dens
TC Avg Temp
101

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents